Connecting Violin Memory Arrays to IBM AIX and PowerVM
13 www.vmem.com
5. Change NACA bit for all the LUNS you plan to export on AIX Hosts and check that it is successful on
the LUNS that you want.
6. Save the NACA bit settings
# write mem
5.3 Initiator Group Creation
Note: If setting up a VIO environment, it is recommended to set up separate Initiator Groups for LPAR boot
LUNS (one per LPAR) and data LUNS (one per cluster).
1. Create IGROUP. Create (Add) a new Initiator group (IGroup) by clicking on “add IGroup”, provide a
name unique to the hostname.
2. Ensure that the Zoning is done and the HBA’s can see the Array Targets based on the topology
decided.
Then Select the right HBA WWPNs you want to be associated with the iGroup and hit “save.”
Then assign initiators to Igroup and click OK.